PROFI-DOM — construction company +7 (777) 327-97-34
ENRUKZ

What to clad a timber house with: 6 facade materials, shrinkage and a ventilated facade

Reading time: 22 minutes
A modern timber house with facade cladding — choosing finishing materials

A timber house is clad to protect it from moisture and wind and to improve its appearance. The main rule is that the cladding must not prevent the timber from breathing and must allow for shrinkage. The best options are: block house, planken, imitation timber, vinyl and fibre cement siding. The key conditions are a 40–60 mm ventilation gap and sliding fasteners.

Should a timber house be clad — arguments for and against

Timber house with and without cladding — arguments for and against facade finishing

Exterior finishing of a timber house is a frequent question, so let us examine it in detail. Before choosing a material, it is worth understanding whether your house needs cladding at all. The answer depends on the condition of the timber, the climate and your goals.

When cladding a timber house is really necessary

Cladding is essential if the timber has lost its tightness — gaps have appeared, the walls are draughty, or the house stands in a region with frequent rain and strong winds, as is the case in the foothills of Almaty. Shrinkage of the log frame is often uneven on sites with differences in elevation, forming gaps of up to 10–15 mm between the courses, through which up to 30–40% of the heat escapes. Without cladding with insulation (mineral wool 50–100 mm) and a windproof membrane (such as “Izospan A” or “Yutavek”), the corners freeze right through in Almaty winters, when the thermometer drops below -25°C. In such conditions exposed timber quickly takes on moisture, especially during the rainy season and spring snowmelt, which triggers rotting processes. Cladding with a ventilation gap extends the service life of the timber by 15–20 years — we have repeatedly seen how after 5 years without protection the bottom courses turned to dust, while neighbouring houses with a ventilated facade have stood for decades.

When cladding is optional — the house can be left as it is

If the timber is of good quality, the wall thickness is from 200 mm, and the house was built more than 2 years ago and has passed its main shrinkage, cladding is optional and may be purely decorative. Glued laminated timber with a section of 200x200 mm from trusted manufacturers, or profiled timber at natural moisture content after a full shrinkage cycle (12–18 months), retains heat no worse than an insulated wall: its thermal conductivity is 0,15 W/(m·°C), comparable to aerated concrete D400. In this case it is enough to treat the timber with an antiseptic (for example, Senezh Ecobio or Tikkurila Valtti) and a tinting compound — this is 3–4 times cheaper than cladding and preserves the natural vapour permeability of the walls. Houses made of dry profiled timber 200 mm with quality caulking do not require additional insulation — a protective treatment once every 5–7 years is sufficient.

When cladding can do harm — the main risks

Cladding is harmful if it is installed without a ventilation gap, with a vapour-impermeable material (foam plastic, EPS without calculation) or before active shrinkage of the log frame is complete. The vapour permeability of timber (0,06 mg/(m·h·Pa) for pine) is 10–15 times higher than that of foam plastic (about 0,005 mg/(m·h·Pa)), so in winter moisture from the room meets an impermeable layer and condenses on the cold boundary. On Almaty projects we have repeatedly encountered situations where owners, wanting to save money, nailed foam plastic directly to the timber — a year later a black coating of mould formed beneath it, and the timber softened to a depth of up to 5 mm. Moisture is trapped between the timber and the cladding, creating an ideal environment for fungus — the house begins to rot from the inside within 3–5 years, with no way to save the courses without completely dismantling the facade. Therefore, before installation, be sure to check the dew point calculation for your region.

How to make a decision — a checklist of 4 questions

  • Timber thickness: less than 200 mm — cladding with insulation is essential, a wall thinner than 180 mm freezes through in Almaty winters at -20°C.
  • Age of the house: less than 2 years — expect shrinkage, the active shrinkage of profiled timber can be 5–7 cm per floor.
  • Condition of the walls: gaps of more than 3 mm or draughts — cladding with caulking solves the tightness problem.
  • Climate: in windy and rainy areas (the foothills of the Trans-Ili Alatau), the cladding protects against driving rain that beats into the joints of the timber.

What to clad a timber house with — an overview of facade materials

Different materials for cladding a timber house: block house, siding, stone, porcelain stoneware

Choosing the material for cladding a timber house is a balance of price, durability, vapour permeability and appearance. Let us look at 6 main options.

Block house — imitation of rounded logs

Block house is a wooden panel with a convex face that imitates a rounded log, 20–45 mm thick and 90–190 mm wide. The material is made from pine, larch or cedar; larch and cedar are naturally resistant to rot, while pine is 30–40% cheaper but requires treatment against blue stain every 3–4 years. Installation is carried out on battens with a 40–50 mm ventilation gap, and the panel's tongue must always face upwards — this prevents rainwater from seeping into the joint. In the Almaty climate, with humidity swings from 30% in summer to 70% in winter, larch block house warps the least — up to 2 mm per 3 metre of length, whereas pine may warp by 5–7 mm. Before purchasing, check the moisture content of the panels: 12–16% is acceptable for exterior finishing; above that, the panels will begin to crack already in the first season.

Plank cladding (decking board) — a sleek and modern facade

Planken is a planed board with bevelled or rounded edges, installed with a gap of 3–5 mm for ventilation; the standard cross-section is 20×90–140 mm. Unlike block house, planken has no tongue-and-groove joint — each board is fastened separately, which makes it easier to replace a damaged element without dismantling half the facade. It is available in two versions: straight planken (strict rectangular edges) and bevelled (a 45° chamfer at the edges, creating a pronounced wall relief). Larch is considered the optimal choice for planken — it gives minimal warping and needs no finish coating other than UV-filter oil. Thermo wood (pine or ash treated at 180–230°C) costs 50–70% more, but its geometry is stable even after the freeze-thaw cycles typical of an Almaty winter with 20–30 fluctuations through zero per season.

Imitation timber — an even wood-look wall

Imitation timber consists of panels 18–35 mm thick with a flat face and a tongue-and-groove joint, which after installation create a smooth wall visually indistinguishable from profiled timber. The width varies from 90 to 190 mm, and the length reaches 6 metres, which allows horizontal joints to be minimised. The material gives the smoothest surface among wooden alternatives but requires perfect batten frame geometry — a deviation of more than 2 mm per 2 metre will be noticeable at the panel joints. For facades, only the Extra or Prima grade is used: they allow no more than one knot per 1,5 linear metres, and moisture content is controlled within 10–14%. In Almaty's dry air (30–40% humidity during the heating season), imitation timber made of Angara pine shows the least shrinkage — up to 1,5% of its width, whereas ordinary pine may shrink by 3–4%, forming gaps in the joints.

Vinyl siding — a budget-friendly and practical option

Vinyl siding is PVC panels 0,9–1,2 mm thick that do not rot, need no painting and last 30–50 years, and the price is the lowest among all cladding materials (from 2500 to 4500 KZT per m² including trim elements). The main limitation of vinyl is its high coefficient of thermal expansion: during installation a gap of 5–7 mm must be left for temperature deformation, and the panels must not be fixed taut. With Almaty's temperature swings from –25°C in winter to +40°C in summer sun, the length difference of a 3,6 m panel can reach 8–10 mm — if the gaps are not observed, the siding will ripple within the first year. Quality vinyl from American (CertainTeed, Mitten) or Canadian (Kaycan, Gentek) brands contains titanium dioxide and UV stabilisers that slow fading: after 10 years the colour saturation decreases by 10–15%, while budget alternatives without stabilisers decrease by 40–50%.

Fibre cement siding — durability and fire safety

Fibre cement siding consists of panels made of cement, sand and cellulose fibres 8–12 mm thick that do not burn (class NG), do not rot and last more than 50 years — this is critical for wooden houses, where fire breaks on individual housing construction plots are often 6–8 metres instead of the standard 10–12. The material is 2–3 times heavier than vinyl (15–25 kg/m²), so it requires reinforced battens — 40×50 mm battens at 400 mm spacing instead of the usual 600 mm, and for lightweight frame houses it may be excessive in terms of load on the foundation. Leading manufacturers — the Japanese company KMEW (service life up to 60 years), the Belgian Eternit and the Russian Tandor — produce panels with an acrylic coating that retains its colour for 15–20 years. Cutting fibre cement produces silica dust — work with an FFP3 respirator and use a wet-cutting tile saw: this reduces dust generation by 80% and extends the life of the blade.

Metal siding — strength and resistance to mechanical loads

Metal siding is steel or aluminium panels with a polymer coating 0,4–0,6 mm thick, resistant to impacts, temperature changes and UV. The steel version (galvanised + polyester/pural) withstands hail up to 20 mm and mechanical loads — for example, a blow from a branch leaves no dent, unlike vinyl; the aluminium version is 2,5 times lighter (3–5 kg/m² versus 7–9 kg/m² for steel), but softer and requires careful installation because it kinks when bent. Cutting with an angle grinder overheats the polymer coating — after 1–2 years corrosion appears at the cut, so use tin snips or a jigsaw with a metal blade, and treat all cuts with anti-corrosion primer. For a climate with frequent rain and high solar activity (280–300 sunny days a year), choose a pural coating (50 microns thick) or PVDF (80 microns) — they keep their colour for 25–30 years, whereas polyester (25 microns) fades within 8–12 years.

How to allow for timber shrinkage when installing cladding

Installing cladding on a timber house with allowance for shrinkage — expansion gaps and sliding fasteners

How to finish a timber house is a frequent question, so let us examine it in detail. Shrinkage of the log frame is the main technical nuance that distinguishes cladding a timber house from a brick or frame one. Ignoring this process leads to deformation of the facade.

What is log frame shrinkage and how long does it last

Shrinkage of a log frame is the natural reduction in wall height caused by the timber drying out and the inter-crown insulation compressing. For a house made of timber of natural moisture content, shrinkage amounts to 3–10% of the wall height and lasts 1–2 years. In Almaty, where seasonal humidity swings are especially pronounced due to the proximity of the mountains, the process can drag on for up to 3 years in houses made of kiln-dried timber with a moisture content of 18–22%. Inter-crown insulation — jute or flax felt — compresses under the load of the upper crowns by 30–50% of its original thickness in the first year. The most active shrinkage occurs in the first 6 months — up to 70% of the total value. If you clad the house during this period, the cladding may warp or tear at the joints — and redoing the facade will cost more than waiting.

Sliding fasteners — how the cladding should not hinder shrinkage

Sliding fasteners are special brackets or plates with oval holes that allow the battens and cladding to move down smoothly with the shrinkage of the log frame, without deforming or creating stress in the structure. In our work we use two types: galvanised steel “sleds” with 20–30 mm of travel and L-shaped sliding supports with a vertical slot for the screw. For a house 3 metres high made of timber of natural moisture content, fasteners with a travel allowance of at least 45–50 mm are needed — in case shrinkage exceeds the calculated 10%. In Almaty conditions, where timber takes on moisture in winter and expands slightly, and dries out in summer, sliding fasteners compensate not only for shrinkage but also for seasonal fluctuations — up to 3 mm per metre of height. Ordinary screws fix the battens rigidly to the timber — with shrinkage of 5 cm on a wall 3 metres high, the cladding either tears or bends in a “wave”. Sliding fasteners rule out both scenarios.

When you can clad a timber house — timing and signs of readiness

A timber house can be clad no earlier than 1 year after the log frame is assembled, and a house made of timber of natural moisture content — after 1,5–2 years. The sign of readiness is timber moisture content below 20% and no cracks at the joints. Moisture content can be checked with a household moisture meter: the measurement is taken at a depth of 10–15 mm at three points on each wall — at the bottom, in the middle and under the eaves. In Almaty, because of the dry summer and humid winter, the spread of readings can reach 5–6% between seasons, so measurements are taken twice — in May and September. An additional sign: the gaps between the courses have stopped widening — if the gap between the timbers has not changed for a month, active shrinkage is over. Even after active shrinkage is complete, the timber continues to “breathe” — seasonal fluctuations in humidity change its geometry by 1–3 mm per metre. That is why sliding fasteners are always needed, not only in the first year.

Allowance for shrinkage — how to leave a gap above the cladding

Above the top edge of the cladding an expansion gap is left — 10–15 mm for every metre of wall height. For a house 3 metres high the gap will be 30–45 mm, which is then covered with a decorative flashing or eaves overhang. In practice we allow a margin: for timber of natural moisture content — 15 mm/m, for kiln-dried — 10 mm/m. In houses with an attic, where the walls of the first floor reach 3,5–4 metres, the gap comes to 50–60 mm — it is masked with a wide apron of galvanised steel with a polymer coating. An important nuance: the gap is calculated not from the current top of the wall, but from the design final height after shrinkage — for this purpose reference marks are placed on the corners when assembling the log frame. If the gap is made smaller than calculated, within a year the cladding will press against the eaves and begin to bend. If larger, the flashing will not cover the slit, and snow and rain will blow into it.

Ventilated facade and insulation — how timber should breathe

Ventilated facade of a timber house with insulation and an air gap for the walls to breathe

Timber at natural moisture content actively releases moisture into the atmosphere. If you clad it tightly, without a gap, the moisture will stay inside the wall and rotting will begin after 2-3 seasons. A ventilated facade is the only way to preserve both the walls and the finish.

How a ventilated facade works for a timber house

A ventilated facade is a structure in which a 40–60 mm air gap is left between the timber and the cladding, through which natural draught draws moisture out of the wall to the outside, preventing it from accumulating and causing rot. At the bottom, a vent is installed on the plinth — a slit with mesh to keep out rodents — and at the top an outlet is left under the eaves. Warm moist air from the wall rises up through the gap, while cool fresh air is drawn in from below — a passive system with no fans that works all year round. The whole structure rests on a batten frame made of 50x50 mm timber or metal profile, to which the insulation, windproof membrane and final cladding are fixed. If siding is nailed directly to the wall instead of a batten frame, there will be no ventilation gap and the moisture will be trapped in the timber. Before installation, be sure to check that the vents are not blocked by insulation or membrane — this is the most common mistake and nullifies all the ventilation.

What ventilation gap is needed between the timber and the cladding

The ventilation gap between the timber and the cladding should be 40–60 mm. Less than 40 mm — ventilation is ineffective, moisture stagnates and mould develops; more than 60 mm — heat is lost and the cladding's fastening is weakened, especially under wind loads. For the Almaty foothills (Medeu district, Kamenskoye Plateau) with their high humidity and sharp temperature swings, we recommend a gap of 60 mm, while for dry steppe zones such as the Ili district 40 mm is sufficient. The universal value for Almaty's climate is 50 mm: it provides both draught reserve and fastening rigidity. If you use insulation 100 mm thick or more, the ventilation gap is measured from the outer surface of the insulation, not from the wall — otherwise the actual gap will be smaller than the design value.

Is a vapour barrier needed when cladding a timber house

A vapour barrier on the timber side is needed only in one case — if you are insulating the house with mineral wool. The vapour barrier film protects the insulation from moist air from the room, preventing it from getting wet and losing its thermal insulation properties. Without it, water vapour from the rooms passes through the timber, condenses inside the mineral wool, and the wool stops working after just one winter. If insulation is not planned, a vapour barrier between the timber and the cladding is not needed and is even harmful — it traps moisture in the timber, disrupting natural diffusion. In this case, a windproof membrane outside the insulation is sufficient: it lets vapour out of the wall but prevents moisture from the street getting inside the assembly. The difference is simple: a vapour barrier goes on the room side, windproofing goes outside, and they must not be swapped.

Should a timber house be insulated when cladding

Insulation when cladding is needed if the timber thickness is less than 200 mm or the house is located in a region with cold winters — for Almaty and the region these are the foothills (Kamenskoye Plateau, Butakovka), where the average January temperature drops below -15 °C. In other cases, insulation is unnecessary and can do harm if vapour permeability is compromised. For 200 mm timber in the climate of the Almaty plain, insulation is not required — sealing the seams with jute felt and proper cladding with a 50 mm ventilation gap are enough. An extra layer of insulation without calculating the dew point leads to the wall freezing: moisture condenses inside the assembly, the timber starts to rot and the cladding deforms. Before deciding on insulation, order a thermal imaging survey — it will show the actual heat losses of your particular house.

Which insulation to choose for a timber house

For a timber house, only vapour-permeable insulation is suitable — mineral wool (stone or glass wool) with a density of 30–50 kg/m³. Expanded polystyrene and XPS do not let vapour through, which leads to the timber becoming wet and rotting: the dew point shifts inside the wall, and moisture condenses at the timber-insulation boundary. The thickness of the insulation is calculated according to the dew point — for 150 mm timber in Almaty's conditions, 50–100 mm of mineral wool is sufficient. More does not mean better: an excessive layer shifts the dew point deeper into the wall, causing condensation and destruction of the timber from the inside. On the outside, the insulation must be covered with a windproof membrane (for example, Izospan A or Tyvek), and at the bottom a gap of 10–15 mm from the plinth is left — so that capillary moisture from the foundation is not absorbed into the mineral wool.

Comparison of cladding materials — what to choose for a timber house

The facade of a timber house is a frequent question, so let us examine it in detail. Once you already know the characteristics of each material, the main question remains — which option will suit your house. Let us compare all the options by key parameters.

Comparison table of materials for cladding a timber house

MaterialService lifeVapour permeabilityPrice per m² (material)Installation complexityFeatures
Block house25–40 yearsHigh (wood)800–1500 ₸MediumRequires antiseptic treatment every 5–7 years
Plank cladding15–25 yearsHigh (wood)600–1200 ₸MediumSimple replacement of individual boards
Imitation timber20–35 yearsHigh (wood)700–1400 ₸MediumRequires perfectly level battens
Vinyl siding30–50 yearsLow (PVC)400–800 ₸LowRequires a gap for thermal expansion
Fibre cement siding50+ yearsMedium1500–3000 ₸HighHeavy, requires reinforced battens
Metal siding30–50 yearsLow (metal)500–1200 ₸MediumRequires anti-corrosion treatment of cut edges

Which material to choose for different purposes — practical scenarios

For maximum durability and fire safety, choose fibre cement siding; for a budget practical solution — vinyl; to preserve the wooden look — block house or imitation timber; for a modern minimalist facade — planken. Fibre cement panels from Japanese brands (KMEW, Nichiha) withstand up to 100 freeze-thaw cycles and do not burn, but their installation requires a reinforced frame due to their weight of 16–20 kg/m². Vinyl panels from Döcke or FineBer offer the lowest price per square metre, but in direct sun on the southern side they fade within 8–10 years — in the foothill areas (Medeu, Kamenka) this happens noticeably faster due to UV reflection from snow. Block house made of Siberian larch is 30% more expensive than pine, but does not require antiseptic treatment for the first 10 years. If the house stands in a wooded area with high humidity, wooden materials (block house, planken) will require treatment once every 3–5 years; for dry steppe regions, vinyl or metal is more practical.

Which is cheaper — cladding a timber house with siding or plank siding

Vinyl siding is the cheapest option: the material costs 400–800 KZT/m², installation is simple and quick, and a crew of three people closes the facade of an average house in 5–7 days. Planken is more expensive (600–1200 KZT/m² for the material) and requires skilled installation with a milled bevelled rebate profile — labour costs are 30–50% higher. For a facade of 120 m², the difference in the final turnkey price will be 80–150 thousand KZT in favour of vinyl. However, when calculating the full cost of ownership over 20 years, planken may prove more economical: vinyl fades after 10–15 years and needs replacing, while planken is refreshed by sanding and staining for 20–30% of the price of new material.

Mistakes when cladding a timber house — what must not be done

Even quality material will not save you if installation mistakes are made. Here are 5 of the most common problems that turn cladding into a source of trouble.

Mistake 1 — installing the cladding without a ventilation gap

The most common and dangerous mistake is fastening the cladding flush against the timber, without a ventilation gap. Moisture from the wall cannot evaporate, condenses on the inner side of the cladding, and after 2–3 years mould and fungus appear beneath it. Timber of natural moisture content actively releases moisture during the first year of use — up to 3–5 litres of water per cubic metre of wood. If this moisture has nowhere to escape, it accumulates in the enclosed space between the wall and the cladding. The minimum gap for a ventilated facade is 40–60 mm, and it must work as a continuous vertical channel from the plinth to the eaves. If the cladding has already been installed without a gap, the only way to fix the situation is complete dismantling and reinstallation with a ventilated facade. “Blowing” ventilation through the soffits does not work if there is no vertical channel.

Mistake 2 — using unsuitable insulation

Using vapour-impermeable insulation (expanded polystyrene, XPS) under the cladding of a timber house is a serious mistake. The timber must breathe, and closed-cell polystyrene blocks the escape of moisture, turning the wall into a thermos with condensation inside. The dew point shifts into the timber, and with temperature swings water begins to accumulate at the timber-insulation boundary. This is especially critical in Almaty's shoulder seasons, when there are frosts at night and +10–15 °C during the day — condensation forms every day. For a ventilated facade over timber, only mineral wool boards with a density of 30–50 kg/m³ are suitable. They are vapour-permeable, do not support combustion and do not sag when installed vertically. Saving 2 times on insulation results in the timber rotting within 5–7 years.

Mistake 3 — fixing the cladding without allowing for shrinkage

Rigid fastening of the cladding to the timber without sliding elements leads to deformation of the facade as the house shrinks. Over 2–3 years the timber settles by 5–10%, and if the siding or block house is fixed rigidly, it warps, cracks or tears off its fastenings. In our practice there was a case: the owner of a house in Kargaly village installed planken with self-tapping screws without sliding brackets — after a year and a half three boards had split, and gaps of up to 2 cm had formed at the joints. The solution is to use sliding brackets and vertical slots for the self-tapping screws. For timber at natural moisture content, the allowance for shrinkage must be at least 5–7 cm per floor. If the house has already settled for 1–2 years, shrinkage is minimal, but expansion gaps are still mandatory.

Mistake 4 — no treatment of the timber before cladding

Many clients believe that since the timber will be covered by cladding, it does not need treating. This is a fatal mistake: under the cladding an ideal environment for fungus and mould develops, especially if the ventilation gap is insufficient or compromised. In summer the temperature under the cladding is 5–8 °C higher than outside, and humidity stays at 70–80% — — ideal conditions for spore formation. Before installing the cladding, the timber must be treated with an antiseptic in 2–3 coats, with emphasis on the end grain (it absorbs moisture 10 times more actively). Use products for hard-to-reach surfaces with long-term protection (15–20 years). Treatment after the cladding is installed is no longer possible.

Mistake 5 — ignoring ventilation of the under-roof space

If the cladding is installed with a ventilation gap but there are no vents at the bottom and top, ventilation does not work. Air must enter from below (through a perforated plinth flashing) and exit at the top (under the eaves overhang), creating natural draught. Without a difference in height, the airflow stops — physics does not allow air to move in a closed horizontal channel. The area of the vents must be at least 1/100 of the facade area. For example, for walls of 50 m² you need 0,5 m² of total vent cross-section. If the vents are clogged with debris or insulation, the ventilation gap turns into a greenhouse — humidity under the cladding reaches 90%, which is guaranteed to cause the timber to rot within 3–5 years.

Conclusion

We have covered the key points of cladding a timber house — from choosing the material to accounting for shrinkage and ventilation. Here are the main takeaways that will help you make a decision.

Key takeaways

  • Cladding a timber house is not a decorative but a protective measure. Without it, under the influence of UV rays and precipitation the timber loses colour, cracks and begins to rot after 5–7 years in the Almaty climate with sharp temperature changes.
  • The choice of material depends on the budget and weather conditions. Vinyl siding is affordable and practical for southern slopes, block house is attractive and warm for winter living, and larch planken is durable and repairable for the humid areas of Medeu.
  • Timber shrinkage is the main enemy of rigid installation. Use sliding fastenings and expansion gaps of 30–50 mm above the windows, otherwise the cladding will deform in the very first heating season.
  • A ventilated facade is an essential condition for durability. A 40–60 mm ventilation gap and vents at the bottom and top prevent mould and rotting of the timber under the cladding even with Almaty's capricious humidity.
  • Do not economise on antiseptic and insulation. Treating the timber before cladding and choosing vapour-permeable mineral wool with a density of 35–50 kg/m³ is an investment in 20–30 years of facade service without rework.

About the author

Heinrich Schmidt

A specialist in timber and hinged facades. Collaborates with the PROFI-DOM workshop in Almaty.

Cladding of timber houses: ventilated facade, siding, plank cladding, imitation timber; shrinkage.

Phone:+7 (777) 327-97-34Our address:Almaty, Makataev St., 47, office 325 (Partner Business Centre)Daily: 9:00–21:00 (by appointment)