How to insulate a house under siding: choosing insulation, the ventilated facade build-up and installation technology
Insulating a house under siding is a ventilated facade technology where the insulation (mineral wool or polystyrene foam) is laid between the battens of the lathing, covered with a wind barrier, and a ventilation gap of 40-60 mm is left to let moisture escape. For Almaty's climate, the optimal insulation thickness is 100-150 mm.
Why insulate a house under siding
Siding on its own does not provide warmth. Without insulation beneath it, the walls stay cold and freeze in winter. Let us look at why insulation under siding is a necessity, not an option.
Why siding without insulation does not solve the warmth problem
Siding is decorative cladding, not thermal insulation. It protects the walls from rain and wind but does not keep heat inside the house. The thin air gap between the siding and the wall gives only a minimal effect — in winter the wall still stays cold, and the dew point shifts inside the structure. In Almaty houses made of aerated concrete and wood, this leads to freezing corners and mould forming by January. Moreover, without insulation, condensation accumulates right within the wall rather than on its surface, and it can only be noticed by dark patches on the wallpaper. If you clad a house with siding only, the walls will freeze in winter and heating will consume 30-40% more energy — a direct blow to your budget.
What proper insulation under siding delivers
A correctly built insulated assembly under siding reduces a house's heat loss by a factor of 2-3, shifts the dew point into the insulation and protects the walls from freezing. The layer thickness is selected by thermal engineering calculation: for the Almaty climate — from 100 mm of basalt wool on aerated concrete and from 150 mm on a wooden log frame. The insulation acts as a buffer — in winter it keeps the heat inside, preventing the wall from cooling, and in summer it blocks overheating: the house is 5-7°C cooler than outside at +35°C. In our practice, owners of frame houses in the Nurlytau microdistrict cut their gas consumption for heating by half after insulating under siding — from 800 to 400 cubic metres per month. An added bonus is that in summer the insulation acts as a thermos: the house stays cool even if it is +35°C outside.
When insulation under siding is essential
Insulation under siding is essential for houses made of aerated concrete, wood and frame structures — without thermal insulation, these materials freeze through in a single winter. Aerated concrete of density D400 with a wall thickness of 300 mm has a heat transfer resistance of about 1.5 m²·°C/W against a norm of 2.8-3.0 for Almaty — without insulation the wall does not retain heat. For brick and concrete walls, insulation is also recommended if the wall thickness is less than 50 cm or the house was built without regard for the region's climate. For example, old brick houses in central Almaty with wall thicknesses of 38 cm freeze right through in winter — insulation under siding solves this problem in a single season.
Which insulation to choose under siding
The main question when insulating is what to use to insulate a house under siding. There are three main options on the market: mineral wool, expanded polystyrene and XPS. Let us look at what is suitable for a facade and what is not.
Mineral wool — the main insulation for a ventilated facade
Mineral wool with a density of 80-90 kg/m³ is the optimal insulation under siding for a ventilated facade thanks to its high vapour permeability and non-combustibility. This stiffness density (TechnoNICOL TechnoLight Extra, Rockwool Vent Batt slats) holds its shape in the frame and does not sag vertically over time — unlike soft rolls, which shrink by up to 20% in the first season. For the climate of Almaty with its humidity swings, mineral wool is the only material that lets vapour out of the walls to the outside: at the wood-insulation junction, the dew point shifts towards the street rather than into the structure. During installation, a windproof membrane (such as Izospan A) is mandatory over the slats — without it, the wind blows the heat out of the mineral fibre, reducing the insulation efficiency by 30-40%. Unlike foam plastic, mineral wool breathes: moisture from the walls passes freely through the insulation and is removed through the ventilation gap without accumulating inside.
Foam plastic under siding — when it can and cannot be used
Expanded polystyrene (PSB-S 25) can be used under siding only for brick and concrete walls — it is not suitable for wood and aerated concrete due to its low vapour permeability. A density of 25 kg/m³ is the minimum for a facade: looser expanded polystyrene (15 kg/m³) crumbles during installation and, under siding, can sag and create thermal bridges. For a brick house in Almaty, the expanded polystyrene thickness is 100-150 mm, fixed with foam adhesive or umbrella dowels (at least 5 per board). A serious drawback is that expanded polystyrene burns (class G3-G4) and releases acrid black smoke in a fire, so it is not recommended for facades with fire safety requirements. The main risk of expanded polystyrene under siding is that if a mistake is made with the vapour barrier, condensation accumulates beneath it and the walls begin to rot; for a wooden house this is critical.
XPS and PUF — alternative options
XPS (extruded polystyrene foam) is used only for insulating the plinth and foundation under siding, while PU (sprayed polyurethane foam) is used for complex areas with uneven walls. XPS of density 30-45 kg/m³ hardly lets vapour through (0,01 mg/m·h·Pa — 50 times lower than mineral wool), so on wall facades it traps moisture inside, causing mould. PU is sprayed in a layer of 80-120 mm, fills all the gaps and needs no fasteners, but costs 2-2,5 times more than mineral wool and requires a crew with a compressor. Cellulose insulation is a good option for frame houses, but blowing it in requires special equipment and professional installation, which increases the cost of the work.
Comparison of insulation materials under siding
| Parameter | Mineral wool | PSB-S foam plastic 25 | XPS | PUR |
|---|---|---|---|---|
| Density, kg/m³ | 80-90 | 25 | 30-45 | 40-60 |
| Vapour permeability | High | Low | Very low | Low |
| Flammability | NG (non-combustible) | G3-G4 | G3-G4 | G2-G3 |
| For which walls | Any | Brick, concrete | Plinth, foundation | Any |
| Thickness for Almaty, mm | 100-150 | 100-150 | 80-100 | 80-120 |
| Installation complexity | Medium | Low | Medium | High |
Soft insulation materials (low-density glass wool) are not suitable for a facade under siding — they sag and lose their shape, forming voids in the frame.
Ventilated facade assembly under siding
An insulated assembly under siding is not simply “insulation + siding” but a multi-layer structure where each layer performs its own function. Let us break down the correct sequence.
What a proper insulation assembly consists of
A correctly built insulated assembly under siding consists of five consecutive layers: wall → vapour barrier (for wood and frame) → first level of batten → insulation boards → windproof membrane → counter-batten → siding. The vapour barrier is fixed tight against the wall — it blocks water vapour from the room, preventing condensation within the mineral wool. A superdiffusion membrane is installed over the insulation: it releases vapour from the mineral wool outwards but does not let atmospheric moisture back in, unlike roofing felt or tar paper, which “seal” moisture inside and cause rot. The counter-batten of 40×50 mm timber, nailed over the membrane, creates a ventilation gap between the insulation and the siding — in conditions of sharp temperature swings in spring and autumn, this gap is the only safeguard against the mineral wool getting wet at above-zero temperatures and during night frosts. If even one layer is omitted — for example, replacing the wind protection with ordinary polyethylene — the assembly stops breathing, and the insulation turns into a wet lump within a season and a half.
Vapour barrier — needed or not
Vapour barrier under the insulation is mandatory for wooden and frame houses — without it, moist air from inside condenses within the mineral wool, and thermal protection drops by 30-40% in the very first heating season. For brick and aerated concrete walls, a vapour barrier can be omitted provided the walls are plastered on the inside or have a finish with low vapour permeability — vapour hardly passes through dense plaster. In frame houses, a reinforced vapour barrier with an aluminium reflective layer is used: it not only holds back vapour but also returns some of the heat to the room by reflecting infrared radiation, which delivers 5-7% savings on heating. A typical beginner's mistake is fixing the vapour barrier on the wrong side: the rough side must face into the room so that condensation is retained on it rather than running down into the mineral wool. Before installation, tape all the joints between the sheets with butyl rubber tape — ordinary tape peels off within a week in frost, and the airtightness of the assembly is lost.
How the ventilation gap works in the assembly
A ventilation gap of 40-60 mm between the insulation and the siding is a mandatory element of the build-up; without it the insulation gets wet and loses up to 50% of its thermal insulation properties due to the lack of ventilation. Cold air enters through the lower vents (perforated soffits or gaps in the plinth), moves upwards along the wind barrier membrane, takes residual moisture from its surface and exits through the upper vents under the eaves. In the Almaty climate, where winter can bring up to 30 freeze-thaw cycles, the ventilation gap is critically important — during the day, when temperatures are above zero, moisture condenses on the membrane, and at night, if there is no gap, it freezes and destroys the structure of the mineral wool from the inside, turning it to crumbs within two seasons. The counter-batten for the ventilation gap is made from antiseptic-treated timber 40×50 mm with a spacing of 600 mm — this provides rigidity for fixing the siding and a sufficient channel for air. The lower vents must also be protected with mesh against rodents: mice actively climb into facades in autumn, and without mesh they settle right in the insulation, building nests and tunnels there.
Assembly for different wall types
| Wall type | Vapour barrier | Insulation | Wind protection | Ventilation gap | Features |
|---|---|---|---|---|---|
| Wooden timber | Required | Mineral wool 100-150 mm | Required | 50-60 mm | Antiseptic before installation |
| Brick | Not required | Mineral wool or foam plastic | Required | 40-50 mm | Foam plastic is acceptable |
| Aerated concrete | Not required | Mineral wool 100-150 mm | Required | 50-60 mm | Mineral wool only |
| Framed | Required | Mineral wool 150-200 mm | Required | 50-60 mm | Reinforced vapour barrier |
The composition of the insulated assembly under siding depends on the wall material — what works for brick can ruin a wooden house through excessive moisture. For the Almaty climate, 100 mm of mineral wool is the minimum threshold for walls; 150 mm provides a margin of warmth without increasing winter heating costs.
Wind protection and the ventilation gap — why they are critical
The wind barrier and the ventilation gap are two elements without which insulating a house under siding makes no sense. Let us look at which membrane to choose and what gap to leave.
Which wind protection membrane to choose under siding
Under siding you need a vapour-permeable windproof membrane with a vapour permeability of at least 1000 g/m²/day — it releases vapour from the insulation but does not let moisture in from outside. On the Almaty market, Tyvek, Izospan AM/AS and Ondutis A100 — membranes are popular; all three provide the required vapour permeability but differ in tear strength. Tyvek withstands installation loads of up to 200 N/5 cm, whereas Ondutis is around 140 N/5 cm, which is critical in strong winds in the foothill districts (Medeu, Bostandyk). The membrane is fixed with the matt side against the insulation and the glossy side outwards: mixing up the sides means trapping vapour in the mineral wool. Ordinary polyethylene film as wind protection is a mistake: it does not let vapour through, and the insulation beneath it turns into a wet “compress”, losing all its thermal insulation properties.
How to calculate the height of the ventilation gap
The height of the ventilation gap under siding should be 40-60 mm — this is enough for natural ventilation, but not so much as to lose usable area. The counter-batten is assembled from timber 40×50 mm or 50×50 mm, positioned vertically over the wind barrier — the distance between the battens is made 60-70 cm on centre, strictly to match the siding installation spacing. In areas of higher humidity (closer to the mountain range, the Kamenka and Gorny Gigant districts) we recommend a gap of 50-60 mm, while on dry southern slopes (Alatau, Zerdeli) 40 mm is sufficient. If the ventilation gap is made smaller than 40 mm, the air will stagnate and moisture will not be removed. If it is larger than 60 mm, the load on the siding fasteners increases, and in hurricane winds (September-October in Almaty) the siding may shift on brackets that are too long.
How to fix the wind protection — the main rules
The wind barrier membrane is fixed over the insulation with a construction stapler to the battens, with sheet overlaps of 10-15 cm and the joints sealed with special tape. Horizontal sheets are rolled out from bottom to top so that the upper sheet overlaps the lower one — this way water runs off without getting into the joint. The wind barrier is fixed to every frame post with staples every 30-40 cm, and the puncture points are additionally sealed with the same butyl rubber tape. There must be no slack between the membrane and the counter-batten — it is tensioned taut, otherwise the film will flap in the wind and tear on the rough surface of the timber. If the wind barrier is not installed, the insulation will be blown out by the wind through the gaps in the siding — over 2-3 years heat loss will increase by 30-40%, and dust and dirt will appear in the cavities, which can then only be removed by dismantling the entire cladding.
Insulation technology under siding
Insulating a house under siding with your own hands is a task you can complete without hiring a crew if you know the sequence. Let us break down each stage.
Wall preparation and treatment with antiseptic
Before insulating, wooden walls must be treated with an antiseptic in 2 coats — this protects the wood from fungus and rot for 10-15 years. Water-based products are used for the job (for example, Senozh Ekobio or Neomid 430) — they penetrate deep into the fibres and do not hinder vapour permeability. The first coat is applied with a brush along the grain, the second after 4-6 hours, once the first has dried. Particular attention is paid to the bottom courses and the ends of the logs — these are the areas where moisture accumulates fastest. Brick and aerated concrete walls do not need an antiseptic, but it is worth checking the condition of the joints and sealing cracks with cement mortar, otherwise heat will escape through them regardless of the insulation thickness.
Installation of the first layer of battens
The first level of the batten is installed vertically from 50x50 mm or 100x50 mm timber — its thickness equals the thickness of the insulation, and the spacing is 600 mm (to match the board size). For wooden walls, the timber is fixed with 90-120 mm wood screws, having first levelled the plane with wooden shims. In Almaty's conditions, where humidity fluctuations are significant, we advise using galvanised metal profiles for plasterboard (PP 60×27) — they do not deform from damp, do not rot and last longer than wood. If you do choose wood, treat the timber with the same antiseptic as the walls. A batten spacing of 600 mm is no random figure: the standard width of mineral wool boards is 600-610 mm, and the insulation fits frictionally without additional fixings.
Laying the insulation and fastening with dowels
The insulation boards are laid frictionally between the batten timbers and additionally secured with umbrella dowels — 5-6 per board (at the corners and in the centre). For stone wool with a density of 35-50 kg/m³, disc dowels 120-160 mm long are used depending on the insulation thickness. The boards are laid in a staggered pattern with offset joints — this eliminates through gaps through which heat escapes. If a board fits into the opening too loosely, it is trimmed with a knife to be 1-2 cm wider — the insulation must sit tightly, without gaps, otherwise thermal bridges form. Never leave voids between the board and the timber: even a 2 mm gap reduces insulation effectiveness by 10-15%, and in winter condensation will form in that area.
Installation of the counter-batten grid and the ventilation gap
The counter-battens are mounted horizontally over the wind barrier from 50x50 mm timber — this creates a 50 mm ventilation gap and serves as the base for attaching the siding. Before installing it, a windproof membrane (for example, Izospan A or Tyvek) must be stretched and fixed with a stapler to the first level of the battens. The counter-batten timber is fixed to the first-level battens with 90 mm screws — the same spacing, 600 mm. The direction of the counter-battens must be perpendicular to the first level — this ensures the rigidity of the structure and proper ventilation. In areas with strong winds (the Alatau and Aksai districts), increase the spacing to 400 mm: this way the siding does not vibrate in gusts and the fasteners do not work loose over time.
Insulation of corners and complex areas
The corners of a house are insulated with particular care — the insulation boards are trimmed so that they butt together without gaps, and a continuous layer of wind protection is laid over the top. For external corners, the boards are cut at 45° and laid with an overlap: one board overlaps the other by 10-15 cm to eliminate direct draughts. Internal corners (bay windows, niches) are insulated with whole boards, trimmed to fit — no offcuts narrower than 200 mm, as they do not hold and fall out. The most common mistake at corners is leaving gaps between the boards. Up to 20% of the heat escapes through them, and mould appears in those areas in winter — proven on dozens of Almaty houses where the corners were “weeping” by January.
Common mistakes when insulating under siding
Even with the right choice of material, mistakes can be made that will undo all the effort. Let us look at the five most common ones.
No ventilation gap — insulation gets wet
If you do not leave a ventilation gap between the insulation and the siding, moisture will accumulate in the insulation — within a single season it will become damp and lose up to 50% of its thermal insulation properties. Moisture that escapes from the room through the vapour-permeable wall meets the siding and condenses on the insulation. Without a 40-60 mm gap, the condensate does not evaporate but is absorbed into the mineral wool or foam plastic. In winter the wet layer freezes, turning into ice, which expands and destroys the structure of the material. Wet insulation not only fails to keep the heat in, but also freezes through in winter, destroying the wall from the inside — it is impossible to restore it without dismantling the siding.
Incorrect choice of insulation density
Using soft mineral wool with a density of 30-50 kg/m³ under siding is a mistake: it sags under its own weight, and the upper part of the wall is left without insulation. For a facade under siding, mineral wool must have a density of at least 80 kg/m³ — only such wool does not deform and keeps its shape for its entire service life. Soft rolls, which are placed in floors, are unsuitable for vertical facades: after a year or two a void forms in the upper part of the wall, and the insulation lies in a clump on the plinth. You can check the density by the marking — look for the designation P-80 or the facade series. For a facade under siding, mineral wool must have a density of at least 80 kg/m³ — only such wool does not deform and keeps its shape for its entire service life.
Saving on the wind barrier — the insulation gets blown out
Skipping the windproof membrane means the insulation is blown out by the wind through the gaps in the siding — over 2-3 years heat loss grows by 30-40%. Wind protection costs 5-10 times less than replacing the insulation — saving on it is a false economy: redoing the work will cost the full price of the insulation plus dismantling the siding. Even dense 80 kg/m³ mineral wool without a membrane gradually crumbles under the effect of draughts in the ventilation gap. The vapour-permeable membrane lets moisture out but holds back the insulation fibres and prevents the wind from blowing the heat out. Wind protection costs 5-10 times less than replacing the insulation — saving on it is a false economy: redoing the work will cost the full price of the insulation plus dismantling the siding.
Insufficient insulation thickness — walls freeze through
Insulating under siding with a layer of 50 mm instead of 100-150 mm for Almaty's climate guarantees that the walls will freeze through in winter and shifts the dew point into the interior. If the thickness is insufficient, the dew point ends up not in the insulation but in the wall — moisture condenses inside, causing mould and destruction of the wall material. For Almaty winters with frosts down to -25°C, the minimum layer of basalt wool is 100 mm; for corner rooms and end walls, 150 mm is better. Polystyrene foam of the same thickness provides slightly less protection, but it too should not be laid thinner than 100 mm. If the thickness is insufficient, the dew point ends up not in the insulation but in the wall — moisture condenses inside, causing mould and destruction of the wall material.
Conclusion
We have covered five key points: from material choice to fatal installation mistakes. Here is a summary that will stay in your memory.
Key takeaways
- Insulation under siding — mineral wool of density 80-90 kg/m³. It is vapour-permeable, non-combustible and suitable for any walls. Polystyrene foam — only for brick and concrete.
- The insulation assembly consists of five layers: wall → vapour barrier (for wood) → insulation → wind protection → ventilation gap → siding. Omitting any layer reduces its effectiveness.
- A ventilation gap of 40-60 mm is mandatory. Without it the insulation gets wet and loses up to 50% of its thermal insulation. The counter-batten creates this gap.
- The insulation thickness for Almaty is 100-150 mm. Less means freezing walls and mould. More means excess materials without a significant gain in effectiveness.
- A wind barrier membrane is not an option but a necessity. It protects the insulation from being blown out and from moisture, extending the service life of the build-up to 30-50 years.