How to insulate a brick house on the outside: choosing insulation, calculating thickness and installation technology

Reading time: 19 minutes
Insulating a brick house on the outside: workers installing insulation boards on the facade, sunny day

To properly insulate a brick house from the outside, you need to choose the insulation (polystyrene foam, mineral wool or XPS), calculate its thickness according to the thermal resistance standard for your region, and apply a suitable facade system — wet or ventilated. The main thing is not to make a mistake with vapour permeability and the dew point.

Why insulate a brick house externally

A thermal imaging image of a house's brick wall showing heat loss, brick wall insulation is essential

Insulating a brick house on the outside is a frequent question, so we will examine it in detail. Without external insulation, brick walls let up to a third of the heat escape, forcing the boiler to work to the limit and increasing heating bills.

Why uninsulated brick walls lose heat

Brick, even hollow, has high thermal conductivity — from 0,41 W/m·K for ceramic to 0,87 W/m·K for sand-lime, so a wall 380 mm thick without insulation gives a thermal resistance of about 0,9 m²·°C/W. For the Almaty climate, the standard thermal resistance is about 3,5 m²·°C/W, meaning brickwork without insulation falls short by a factor of 3–4. The main heat losses in a private house occur precisely through the walls — up to 30–40%, which is significantly more than through the roof or a floor on the ground. Insulating the roof adds 0,5–1,0 m²·°C/W of resistance, while external wall insulation adds 2,5–3,5 m²·°C/W at once, so it makes most sense to start upgrading the house's thermal envelope with the facade.

What external insulation of a brick house provides

External insulation shifts the dew point from the thickness of the brick wall into the insulation layer, which prevents the masonry from freezing and mould from forming on the inner surfaces of the walls. With a correct calculation of the insulation thickness, condensation falls inside the mineral wool or expanded polystyrene, while the brick stays dry and is not destroyed by freeze-thaw cycles. On the outside, the insulated facade simultaneously protects the wall from temperature swings — the difference between night-time minus and daytime plus in the city reaches 10–15 °C, and each such cycle reduces the life of the brick by 2–3 years without insulation. Internal insulation of a brick house is a risky solution: it leaves the wall in the sub-zero temperature zone and is guaranteed to create condensation at the brick-insulation boundary, which leads to mould behind the drywall.

When insulating a brick house is mandatory

Insulating a brick house is essential if the wall thickness is less than 640 mm for solid brick or less than 510 mm for hollow brick — such walls do not provide the standard thermal resistance for the climate of the middle latitudes. Even a 510 mm hollow ceramic brick wall without insulation has a heat transfer resistance of about 1,2 m²·°C/W, which is 2–3 times lower than the standard of 3,5 m²·°C/W for Almaty. In winter, cold zones appear on such a wall inside the house — places where the temperature drops below the dew point, and that is exactly where black mould starts to grow. According to our observations, owners of houses with wall thicknesses up to 510 mm encounter freezing of the corners as early as the second or third year of use, especially if the house stands on a windswept plot.

What to insulate a brick house with: comparison of insulation materials

Samples of different insulation materials for a brick house: mineral wool, polystyrene foam, polyurethane foam on a table

Insulating brick walls is a frequent question, so we will examine it in detail. We review the three main insulations for a brick house — polystyrene foam, mineral wool and XPS — by thermal conductivity, vapour permeability, combustibility and price.

Expanded polystyrene (PSB-S-25) for a brick house

EPS PSB-S-25 — is the most budget-friendly insulation with a thermal conductivity of 0.038–0.042 W/m·K, but it is combustible (class G3-G4) and hardly lets vapour through (vapour permeability 0.03 mg/m·h·Pa). When burning, polystyrene foam releases acrid smoke, so on facades above two storeys its use is restricted by fire regulations — mineral wool fire barriers are required around windows and between floors. Installation with adhesive foam and umbrella dowels is standard, and the plaster layer over the mesh protects the material from ultraviolet radiation and mechanical damage. Polystyrene foam is suitable for a wet facade on brick walls, but only provided that the wall does not “breathe” — for example, for sand-lime brick with low vapour permeability this is a safe option.

Mineral wool (stone wool) for a brick house

Mineral wool is a non-combustible insulation (class NG) with a thermal conductivity of 0.035–0.042 W/m·K and high vapour permeability of 0.3 mg/m·h·Pa, which makes it the best choice for brick walls with good vapour permeability. Unlike polystyrene foam, mineral wool does not support combustion and does not release toxic substances when heated — this is critical for houses with attics and attached garages. In a wet facade system, slabs with a density of at least 130 kg/m³ are used (for example, “Technofas” by TechnoNICOL or “Light Batts” by Rockwool), which are laid in two layers with overlapping joints to eliminate cold bridges. For a wet facade, only facade mineral wool with a density of at least 130 kg/m³ is used — looser wool does not hold the plaster layer and sags over time.

XPS (extruded polystyrene foam) for a brick house

XPS is the warmest insulation, with a thermal conductivity of 0.031–0.035 W/m·K, zero water absorption and high strength, which makes it ideal for plinths and ventilated facades. In Almaty districts with high groundwater levels (for example, in the Kulager and Taugul microdistricts), XPS on the plinth prevents capillary moisture from being drawn into the wall, whereas polystyrene foam or mineral wool under the same conditions becomes wet and loses its thermal insulation within 2–3 seasons. The boards are fixed with foam adhesive or bitumen mastic, with additional fastening by disc dowels — 5–6 per board. XPS is 2–2.5 times more expensive than polystyrene foam, but its low vapour permeability (almost zero) requires a mandatory dew point calculation — if installed incorrectly, condensation remains in the wall.

Comparison of insulation materials for a brick house: table

ParameterExpanded polystyrene PSB-S-25Mineral wool (facade)XPS
Thermal conductivity, W/m·K0.038–0.0420.035–0.0420.031–0.035
Vapour permeability, mg/m·h·Pa0.030.30.01
FlammabilityG3-G4 (combustible)NG (non-combustible)G3-G4 (combustible)
Service life, years25–3030–5040–50
Price per m³lowaveragehigh
For which systemwet facadewet and ventilated facadeplinth, ventilated facade

Algorithm for choosing insulation for a brick house

  • For sand-lime brick: polystyrene foam or XPS — the wall's vapour permeability is low (0.05–0.1 mg/m·h·Pa), so insulation with low vapour permeability does not trap moisture and does not cause dampness.
  • For ceramic hollow brick: mineral wool — the wall lets vapour through (0.14–0.17 mg/m·h·Pa), so the insulation must be vapour-permeable to prevent moisture from accumulating at the brick-insulation boundary.
  • For the plinth: XPS — zero water absorption and high compressive strength (0.2–0.5 MPa) protect the foundation from soil heaving and capillary moisture.
  • On a limited budget: PSB-S-25 — polystyrene foam is the cheapest option, but with mandatory fire protection (plaster no thinner than 5 mm, clearances from windows of at least 15 cm).
  • When safety requirements are high: mineral wool is the only non-combustible option of the three, mandatory for facades above two storeys and houses with gas boilers.

What insulation thickness is needed for a brick house

A tape measure measuring the insulation thickness on a brick wall, thickness calculation for a house in Almaty

We explain how to calculate the insulation thickness for a brick wall using the thermal resistance formula, and give ready-made values for different types of brick and wall thicknesses.

How to calculate the insulation thickness for a brick wall

Insulation thickness is calculated using the formula R = d/λ, where R is the standard thermal resistance for the region, d is the layer thickness in metres and λ is the thermal conductivity of the material. For Almaty the standard for walls is R=3.5 m²·°C/W, for brick λ=0.7–0.8 W/(m·°C) depending on the type, for polystyrene foam λ=0.04, for mineral wool λ=0.038–0.042. First we calculate the thermal resistance of the wall itself: divide its thickness in metres by the λ of the brick. For a 380 mm sand-lime brick wall (0.38 m), R_wall = 0.38 / 0.7 ≈ 0.54 m²·°C/W. Then we subtract this from the standard: 3.5 – 0.54 = 2.96 m²·°C/W — this difference must be covered by the insulation. We multiply R_insulation by its λ: for polystyrene foam 2.96 × 0.04 = 0.118 m, that is 118 mm. To perform the calculation you need to know the thermal resistance of the brick wall itself (R_wall = d_wall / λ_brick) and subtract it from the standard R_norm — the difference is covered by the insulation.

Thermal resistance standard for Almaty and other regions

For Almaty, the standard wall thermal resistance is R=3.5 m²·°C/W, for Astana — R=3.8, and for the southern regions of Kazakhstan — R=2.8–3.2. This standard is set by SP RK 2.04-01- and depends on the degree-days of the heating period — for the city this is about 3500 DDH, in Astana — 4800 DDH, in Shymkent — 2800 DDH. The higher the DDH, the more heat escapes through the walls over the winter, so a colder climate requires a thicker insulation layer. For the Moscow region R=3.2, for Siberia — up to 4.5, for southern Russia — 2.5–2.8. The standard depends on the climatic zone — the colder the winter, the higher the required R, so when building or insulating in Almaty, follow the local standards rather than Moscow or European tables.

Finished insulation thickness for different walls

Brick typeWall thickness, mmRequired polystyrene thickness, mmRequired mineral wool thickness, mm
Calcium silicate250150130
Calcium silicate380120–150100–130
Calcium silicate510100–12080–100
Ceramic hollow250100–12080–100
Ceramic hollow38080–10060–80
Ceramic hollow51050–8050–60

The values given are calculated for Almaty standards (R=3.5). For a 380 mm ceramic brick wall (λ≈0.3), the wall's own resistance is higher than that of sand-lime brick, so less insulation is required. The insulation thickness for a brick house is always rounded up to the standard board size (50, 100, 150 mm) — it is better to take 10–20 mm more than less, to reliably cover the standard.

What happens if you choose the wrong insulation thickness

If the insulation thickness is less than the calculated value, the dew point shifts into the wall thickness or onto its inner surface, which leads to freezing of the brick, condensation and mould inside the house. With a shortfall of 30–40 mm of polystyrene foam on a wall of 380 mm of sand-lime brick, in winter the inner surface temperature can drop to 12–14 °C, which is below the dew point (about 9–10 °C at 50% humidity, but at 70% humidity the dew point rises to 14 °C). As a result, dark spots appear on the wallpaper, wooden floors begin to rot, and fungus grows in the corners — eliminating it is harder than laying the correct thickness from the start. Excessive insulation thickness (for example, 200 mm instead of 100 mm) is not dangerous for the structure, but is economically unjustified — an extra 50 mm adds only 10–15% to the thermal protection while doubling the cost.

Wet facade or ventilated facade: which to choose for brick

Two facade options for a brick house: wet and ventilated, choosing the insulation technology

We compare the two main insulation systems for a brick house — the wet facade and the ventilated facade — by technology, vapour permeability, dew point and cost.

What a wet facade is and how it works on brick

A wet facade (EIFS) is a system in which the insulation is glued to the wall, fixed with umbrella dowels, reinforced with fibreglass mesh and covered with decorative plaster, forming a single multi-layer “sandwich”. The brick wall must be primed before installation, and the base plaster layer is applied 3–5 mm thick to conceal the mesh — with spring temperature swings of 15–20 °C per day, a breach of technology causes the plaster to peel at the corners of openings after 5–7 years. Mineral wool for a wet facade is taken at a density of at least 130 kg/m³: less dense wool deforms under the weight of the plaster and cracks. For a brick house, a wet facade with mineral wool is the physically correct solution: the vapour permeability of the layers increases from inside to outside, and the wall “breathes”, removing moisture through the plaster.

What a ventilated facade is and when it is needed

A ventilated facade is a system with a frame of galvanised guides, into which insulation is placed, covered with a windproof membrane, and on top of that the cladding is installed with an air gap of 40–60 mm to let vapour escape. For brick houses in seismic zones (7–8 points), a ventilated facade is preferable: the frame is anchored to the load-bearing wall and prevents the cladding from shifting when the ground moves. Mineral wool for a ventilated facade needs a density of at least 80 kg/m³ — it does not slip in the gap or settle over 10–15 years, and the windproof membrane is installed with an overlap of 10–15 cm and sealed with butyl rubber tape, otherwise dust blocks the vapour escape. A ventilated facade is essential if the insulation is mineral wool and the finish is porcelain stoneware or fibre cement: without the gap, vapour condenses inside the cladding and destroys it.

Comparison of wet and ventilated facades for brick

ParameterWet facadeVentilated facade
Compositionadhesive + insulation + mesh + plasterinsulation + membrane + gap + cladding
Insulationexpanded polystyrene, mineral wool (density from 130 kg/m³)mineral wool (density from 80 kg/m³), XPS
Vapour permeabilitydepends on the plaster (silicone — vapour-permeable)high, thanks to the ventilation gap
Dew pointwithin the insulation (with correct calculation)within the insulation, vapour is released through the gap
Service life25–35 years (until plaster repair)40–50 years
Price per m²low–mediummedium–high
Repairabilitydifficult (re-plastering the facade)easy (replacing individual panels)

The choice of system depends on the insulation: only a wet facade works with polystyrene foam (a ventilated facade with polystyrene foam is a fire hazard), while mineral wool works with both systems, but a ventilated facade requires denser wool (from 80 kg/m³).

Dew point behaviour in wet and ventilated facades

In a properly insulated brick wall, the dew point lies within the thickness of the insulation — in a wet facade, moisture is removed through the vapour-permeable render, while in a ventilated facade it evaporates through the air gap. For brick 380 mm and insulation 100–120 mm, the dew point in a wet facade with mineral wool is located at a depth of 30–50 mm from the outer surface — condensate does not come into contact with the brick, and in a ventilated facade the vapour rises through the gap at a speed of 0,3–0,5 m/s and is removed through the deflectors on the cornice. If the calculation is wrong (insulation thinner than 80 mm for brick 510 mm), the dew point shifts to the brick-insulation boundary: in a wet facade this causes damp patches on the render, and in a ventilated facade it causes ice on the membrane. If the dew point shifts to the brick-insulation boundary, this will inevitably lead to the wall freezing and the insulation breaking down — especially critical for polystyrene, which does not let vapour through.

DIY technology for insulating brick walls

A step-by-step guide to insulating brick walls on the outside — from surface preparation to final finishing — for the wet facade, as the most popular system.

Preparing a brick wall for insulation

Before insulation, the brick wall must be cleaned of dust and old paint, cracks filled with cement mortar and uneven areas over 10 mm levelled out — otherwise the insulation will not fit snugly, forming voids. Solid ceramic brick has a thermal conductivity of 0.56–0.81 W/m·K, but even such a wall becomes a thermal bridge if the joints are weathered 10–15 mm deep. After cleaning, the wall is primed with a deep-penetration compound — this binds residual dust and improves the adhesion of the adhesive to the brick. Pay special attention to old brick walls with weathered joints: the joints must be deepened by 10–15 mm and refilled with mortar, otherwise heat will escape through them even with insulation.

Installing insulation on a brick wall: adhesive and dowels

The insulation is fixed to the brick wall in two stages: first with adhesive (applied around the perimeter of the board and 2–3 dabs in the centre), and after 24 hours — with disc dowels at a rate of 5–8 per m². The adhesive is applied in a strip 80–100 mm wide along the edge of the board and in two or three dabs in the centre — this ensures even contact without voids; for polystyrene foam and XPS, adhesive is also applied to the edge of the board so that the joints are sealed. The boards are installed with staggered joints, like brickwork — in a checkerboard pattern, offsetting the vertical joints by at least 200 mm. For brick walls, use dowels with an expansion zone of at least 50 mm — the brick may be hollow, and a short dowel will not hold, causing the insulation to come away from the wall over time.

Reinforcement and plastering of the wet facade

The reinforcing glass mesh (160 g/m²) is embedded in the first layer of adhesive with an overlap of 100 mm at the joints — this prevents cracks in the render that appear due to temperature deformation. The mesh is pressed into the fresh adhesive with a trowel, starting from the top — it is important that it ends up in the upper third of the render layer, not at the bottom or on the surface. After a day, a second layer of adhesive is applied and rubbed in, and once dry, the surface is primed and the finishing facade render (silicone or silicate) is applied. Cracks in the render of a wet facade are the most common problem, and the cause is almost always incorrect reinforcement: the mesh must be in the upper third of the render layer, not beneath it or on the surface.

Insulation of slopes and plinth as part of the system

Window slopes and the plinth must be insulated — these are areas through which up to 15–20% of heat escapes, and if left without insulation they become powerful cold bridges. Window slopes are insulated with the same material as the walls, but with mandatory reinforcement with perforated corners and the mesh overlapping the wall by 150–200 mm — this prevents a crack where the slope meets the facade plane. For the plinth, only XPS is used, 20–30 mm thicker than on the walls — it does not absorb moisture from the soil and withstands mechanical loads in contact with the blind area. The absence of slope insulation creates cold bridges that negate the effect of wall insulation — on a thermal imager such areas appear as bright orange spots even with a high-quality facade.

Common mistakes when insulating a brick house

We examine the five most common mistakes when insulating a brick house — from choosing the wrong insulation to violating installation technology — and explain what they lead to.

Mistake 1: insulating from the inside instead of the outside

Internal insulation of a brick house is the most serious mistake: the wall remains in the sub-zero temperature zone, the dew point shifts to the inner surface, which inevitably leads to mould and freezing. With external insulation, the wall accumulates heat and remains dry, whereas with internal insulation all the moisture from the warm air condenses right under the insulation, creating an ideal environment for fungus. In Almaty houses with temperature swings from −20 °C in winter to +5 °C during a thaw, condensation on the inner wall appears just a month after such insulation. The exception is internal insulation as a temporary measure in an apartment where there is no access to the facade, but on a private house it is always the wrong solution, which eventually destroys the wall.

Mistake 2: wrong choice of insulation for the type of brick

Using polystyrene foam on ceramic hollow brick is a common mistake: the vapour permeability of polystyrene foam (0,05 mg/m·h·Pa) is 10 times lower than that of brick (0,5 mg/m·h·Pa), which traps moisture inside the wall. In hollow brick, the air chambers accelerate vapour movement, and if a vapour-tight material is placed on the outside, moisture accumulates in the voids — in winter, when it freezes, it expands and destroys the partitions. The Almaty market often offers a universal solution of “polystyrene foam for any brick”, but it suits solid brick, while for hollow brick only mineral wool or XPS with a ventilation gap will do, otherwise after 2-3 seasons the plaster will begin to peel.

Mistake 3: insufficient insulation thickness

Insulating a brick house with a 50 mm layer of mineral wool is a common mistake: in the climate of Almaty, walls 380 mm thick require a minimum of 100 mm of mineral wool (R=2,8), while 50 mm gives R=1,4, which does not meet thermal protection standards. Many clients choose 50 mm based on price — the difference between 50 and 100 mm of mineral wool is about 1500 KZT per square metre, but the saving results in cold walls and excess gas consumption. With a 50 mm layer, the dew point ends up inside the wall rather than in the insulation, which guarantees dampness and mould — in winter there will be condensation on the inner surface of the wall, even if the room is at +22 °C.

Mistake 4: no ventilation gap in the ventilated facade

Installing a ventilated facade without a 40-60 mm gap between the insulation and the cladding is a gross mistake: condensate is not removed, the insulation gets wet, loses up to 50% of its thermal insulation properties and begins to rot. In Almaty houses with high air humidity (up to 80% in winter), a vapour-permeable membrane without a gap cannot cope — moisture condenses on the inner side of the cladding and runs down, soaking the mineral wool. Even with a high-quality vapour-permeable membrane, moisture accumulates without a gap — check that the gap is clean and not blocked by the cladding fasteners, otherwise within six months the insulation will turn into wet wadding that does not keep you warm.

Mistake 5: insulating the plinth without waterproofing

Insulating the plinth of a brick house without prior waterproofing is a common mistake: capillary moisture from the soil rises into the insulation, reducing its effectiveness and causing the foundation to freeze. In Almaty, the groundwater level rises to 1-1,5 metres in spring, and without waterproofing, moisture travels up the brick capillaries to a height of up to a metre, soaking the bottom layer of insulation. Before insulating the plinth, be sure to apply bitumen mastic or roll waterproofing in 2 layers — this will extend the service life of the insulation by 10-15 years and protect the foundation from damage caused by frost heave of the soil.

Conclusion

We have gathered the key principles that will help you avoid mistakes when insulating a brick house — from material selection to installation supervision.

Key takeaways

  • External insulation is the only correct option for a brick house. Internal insulation shifts the dew point into the wall, causing mould and freezing of the masonry within 1-2 seasons.
  • The choice of insulation depends on the type of brick and the facade system. For hollow brick — only vapour-permeable materials (mineral wool); for solid brick — both polystyrene foam and mineral wool, with different thicknesses.
  • Insulation thickness is calculated by a thermal engineering calculation, not "by eye". A minimum of 100 mm of mineral wool for the climate of Almaty, and 150-200 mm for cold regions such as Ust-Kamenogorsk.
  • The insulation system (wet facade or ventilated facade) is chosen according to the wall material and climate. A ventilated facade is mandatory for humid regions and houses with wooden floors — without it, the walls will not breathe.
  • Avoid five typical mistakes: internal insulation, the wrong material, insufficient thickness, the absence of a ventilation gap and waterproofing. Each of them leads not only to heat loss, but also to the gradual destruction of the load-bearing walls.